Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

Advanced Science Letters, vol: 23,7 (2017)

Physical analysis of radiation dose distribution by using cerrobend compensator-based IMRT in linac 6 MV

Ramantisan S., Suryono S., Sutanto H.

Abstract

The using of Cerrobend compensator-based Intensity Modulated Radiation Therapy (IMRT) has been done to investigate the characteristic and analyze the radiation dose distribution that resulted. Compensator-based IMRT is one way of implementing IMRT which is simple and can be applied to various types of radiotherapy unit such as Cobalt60 machine and also Linac. Cerrobend characterization is done by measuring the linear attenuation coefficient (at Linac 6 MV. Furthermore, the manufacture compensator Cerrobend made in accordance with the desired design. Then measuring the radiation dose distribution generated using gafromic film. Further the analysis of the distribution of radiation dose and calculate the value Homogeneity Index (HI) and Conformity Index (CI) was done. The value of the linear attenuation coefficient (Cerrobend using 6 MV Linac is 0,41 cm?1. Please also note that the use made of Cerrobend compensator-based IMRT can improve skin sparing beneficial effects for patients. In addition this Cerrobend compensator-based IMRT can also improve skin sparing beneficial effects for patients. The using of Cerrobend compensator-based IMRT that provides good accuracy in the calculation of the radiation dose that is having a thickness ?5 mm. Homogeneity index (HI) and Conformity Index (CI) on the use of compensator-based IMRT produce varying values, namely HI from 0,13 to 0,89 and CI from 0,12 to 0,97. That varying values are influenced by not only the thickness but also the design of the compensators. © 2017 American Scientific Publishers All rights reserved.

Keyword: Cerrobend; Compensator; Conformity index; Homogeneity index; IMRT

DOI

× How can I help you?